high quality npb output transformer npb 15w | JM
high quality output npb transformer 15w
winding npb number of coil wire diameter in mm number of insulation layers Bp1 1650 0,11mm 7 paperboard 30 microns between layers Bs1 96 0,6 mm 2 paperboard varnish 0,1 mm Bp2 1650 0,11mm 7 30mm cardboard between the layers Bp3 1650 0, 11mm 7 paperboard 30 microns between coats Bs2 96 0,6mm 2 cardboard varnish 0,1 mm Bp4 1650 0,11mm 7 30mm cardboard between layers
because this type of transformer is classic and can be constructed and used in numerous devices npb considered it appropriate to give the full features for those who can ... have the technical capabilities winding ... ..theloun excellent construction and performance.
core width 28mm
the primary is made in layers with intermediate layers of the secondary, so that we have the maximum power transfer and secondly to have completely symmetrical upstream circuits to avoid the phenomena of overload of one leg of the amplifier causing the known flushing of one of the two tubes. if unable to build in the transformer ratio and give one to your wrap to look upon receipt exist multiple downloads to your otherwise coils him wrap kaloumpa as they usually do. such windings have nothing to do with the winding described for the perfect performance.
after completion of all the transformer windings immersed in diluted varnish transformers to penetrate between windings and cover them all gaps. this procedure should be done several times in between long periods to dry the previous varnish spent.
[The entire structure is 20 years ago, because all transformers purchased was type kaloumpas. friend dealing with windings and was a fanatic of perfect functioning and performance showed us how to construct and calculate them.]
Enter the details below or click an icon to log in:
March 2014 K M T W T F S February April 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Recent Articles relay average power fuses measurement of large tensions toroidal transformer and converting electrical connections and mobile telephony systems (Part A) three-phase squirrel cage motors table cos phi improvement in facilities. isolation transformer 230-230 V switch and historic staircase mercury npb table distribution medium power automatic star-delta switching conversion dB movable mirror and fix cables on